型号 | AN8721PV | |
电流规格 | 50A(改制) | |
接线方式 | 1P2W(单相2线 | |
输入阻抗 | 电压:约2MΩ 电流直接输入:约10mΩ 电流传感器输入:约100kΩ | |
满量程峰值因数 | 3 | |
电压额定量程(直接输入) | 15/30/60/100/150/300/600/1000*[V] *1000V满量程峰值因数为1.5 | |
电流额定量程(直接输入) | 100m/200m/500m/1/2/5/10/20/50[A] | |
电压/电流精度范围 | (1%~110%)×量程 | |
功率因数范围 | ±(0.001 ~ 1.000) | |
电压测量精度 | DC 0.5Hz≤f<45Hz 45Hz≤f≤66Hz 66Hz<f≤1kHz 1kHz<f≤10kHz 10kHz<f≤100kHz | ±(0.1%×示值+0.2%×量程) ±(0.1%×示值+0.2%×量程) ±(0.1%×示值+0.1%×量程) ±(0.1%×示值+0.2%×量程) ±({0.07×f}%x示值+0.3%×量程) ±(0.5%x示值+0.5%x量程),±[{0.04×(f–10)}%x示值] |
电流测量精度 | DC 0.5Hz≤f<45Hz 45Hz≤f≤66Hz 66Hz<f≤1kHz 1kHz<f≤10kHz 10kHz<f≤100kHz | ±(0.1%×示值+0.2%×量程) ±(0.1%×示值+0.2%×量程) ±(0.1%×示值+0.1%×量程) ±(0.1%×示值+0.2%×量程) ±({0.07×f}%x示值+0.3%×量程) ±(0.5%x示值+0.5%x量程),±[{0.04×(f–10)}%x示值] |
有功功率测量精度 | DC 0.5Hz≤f<45Hz 45Hz≤f≤66Hz 66Hz<f≤1kHz 1kHz<f≤10kHz 10kHz<f≤100kHz | ±(0.1%×示值+0.2%×量程) ±(0.3%×示值+0.2%×量程) ±(0.1%×示值+0.1%×量程) ±(0.2%×示值+0.2%×量程) ±(0.1%x示值+0.3%x量程),±[{0.067×(f–1)}%x示值] ±(0.5%x示值+0.5%x量程),±[{0.09×(f–10)}%x示值] |
有功功率测量范围 | 2.2mW~4.4kW@220V,PF=0.01~1 | |
有功功率最高分辨力 | 0.1mW | |
频率测量范围 | DC,0.5Hz ~ 100kHz | |
频率测量精度 | ±0.1%×示值 | |
谐波测量 | 11Hz ~ 600Hz,1~50次谐波含量,总失真度 | |
电能测量范围 | 0~99999MWh (分辨率:1mWh/0.01mAh) | |
电能测量精度 | ±0.2%×示值 | |
电能计时 | 9999时59分59秒 | |
滤波器功能 | 500Hz、5.5kHz电压线路、电流线路和频率滤波 | |
变比范围 | 1.0 ~ 10000.0 | |
数据更新周期 | 100m / 250m / 500m / 5[s] | |
报警功能 | 5组,电压、电流、功率上/下限、门限设定 | |
控制接口 | 标配:RS-232; 选配:RS-485 | |
外形尺寸 | 213(W, 前塑壳)×88(H, 前塑壳)×380(D, 含接线柱) mm | |
开口尺寸 | 210(W)×85(H) mm | |
底脚高度 | 15 mm | |
整机重量 | 约2kg | |
整机功耗 | 约10VA |